High Accuracy
5 Hours offline woking after full charged
All-around datas on the screen
Door-free design, prevent leakage
Related Product Searches:Syringe Pump & Infusion Pump,High Quality,Syringe pump, ce approved syringe pump,V6&V8
Type | VoluPro V6 | VoluPro V8 |
Applicable IV Set | All standard Iv Set | All standard Iv Set |
Pumping method | Dactylic creeping type | Dactylic creeping type |
Speed range | 1~600ml/h; | 1~2000.0ml/h |
Increment | 1ml/h | 0.1ml/h |
Bolus | 600 ml/h | 1000ml/h |
Accumulated Volume | 1ml-9999 ml | 0.1ml~9999.9ml |
Accuracy | ±2% after calibration | ±2% after calibration |
KVO Speed | 1ml/h (KVO auto run after block) | Adjust Range:1ml/h~5.0ml/h |
Mode | Speed mode | Speed mode, Time mode & Weight mode |
Speed mode | Speed:1~600ml/h | Speed: 1~2000.0ml/h |
Time mode | -- | Time: 1~2000 min Volume: 0.1~999.9 ml |
Weight mode | -- | Body Weight: 0.1~300.0kg;Medicine Volume: 0.1~999.9 mg ;Liqid Volume: 0.1~999.9 ml Dose: 0.1~9999.9Units: mg/kg/h, ug/kg/min |
Information display | speed, set volume, accumulated volume, battery, patient bed number, air bubble, blocking alarm, transfusion completion, pressure, flow speed, etc. | speed, set volume, accumulated volume, battery, patient bed number, air bubble, blocking alarm, transfusion completion, pressure, flow speed, ,etc. |
Alarm | Completion, blocking, battery low, air bubble, CPU error, pump stuck, abnormal control, serious power shortage, etc. | Completion, blocking, battery low, air bubble, CPU error, pump stuck, abnormal control, serious power shortage, etc. |
Power | AC 110V~240V, 50/60HZ; DC 12V; Power Consumption 25VA | AC 110V~240V, 50/60HZ; DC 12V; Power Consumption 25VA |
Battery Charging | Automatic battery charge when transfusion pump connected with AC power supply and turned on (full charge needs 8-14 hours), last for over 5 hours operation | Automatic battery charge when transfusion pump connected with AC power supply and turned on (full charge needs 8-14 hours), last for over 5 hours operation |
Environment Requirement | Temperature: 5°C~+40°C, Air pressure: (86~106) kPa,Relative humidity: 80% or below | Temperature: 5°C~+40°C,Air pressure: (86~106) kPa,Relative humidity: 80% or below |